Direct-Pure UP Ultrapure & RO Lab Water Systems

The Direct-Pure UP Ultrapure & RO Lab Water System is an integrated system that produces ultrapure and reverse osmosis (RO) water from tap water directly. Quality of ultrapure water meets or exceeds ASTM, CLSI, CAP, and ISO Type I water standards.

  • Type I ultrapure water and RO water are produced directly from tap water in one single system.
  • Electrical and water compartments are completely segregated, thus safer to operate.
  • System automatically reduces feed water pressure to within working range.
  • Pre-filtration system removes most particles, chlorine and organic compounds to protect RO membrane and EDI module to extend their usable lives.
  • Internal RephiDuo P Pack cartridge further removes oxidants, organics, particles and scaling ions to prevent them from fouling the RO membranes and the EDI module.
  • RO membrane removes over 99% large molecules and particles as well as 95% ions in water.
  • The automatic bypath sends the RO water to the drain if it does not meet preset quality standard.
  • The RO drain water is reused to increase the water yield. It is more environmentally friendly.
  • System automatically rinses a new RO membrane. User does not need to set special rinse program for a new RO membrane.
  • The fully automated control system contains pre-rinse, RO membrane fouling preventing flush, RO membrane and cartridge life monitoring as well as many other programs for convenient operation.
  • The pre-rinsing program starts automatically when a new RO membrane is installed so there is no need for users to set up additional cleaning procedures.
  • Two sets of dual-column purification cartridges work sequentially to ensure thorough removal of ions and organics in water.
  • Ultra purification cartridge is filled with LeFilTM and OrganeFilTM media to remove trace ions and organics.
  • Built-in 185/254 nm dual wavelength lamp reduces TOC level in ultrapure water.
  • The system recirculates automatically every hour to prevent microbial from growing.
  • The system is equipped with a 30-liter PE tank (upgradable to a 60-liter) and a liquid level sensor.
  • Tank vent filter has CO2 scavenger to remove airborne contaminants, including carbon dioxide and keeps water in the tank at best quality possible.
  • A 0.2 μm final filter or ultrafiltration filter (optional) removes final contaminants.
  • Large LCD screen on the water system displays critical information for instant access of system operation and performance parameters.
  • RephiLe can provide full document support to meet users’ GMP, GLP, FDA and other certification requirements.
 Ultrapure Water  RO Pure Water
HPLC mobile phase preparation Preparation of reagent blank solution As sample diluents for GC, HPLC, AA, ICP-MS and other analytical techniques Preparation of buffer and culture media for mammalian cell culture Preparation of molecular biology reagents, etc. Glassware cleaning Washing machine for glassware Water bath water Autoclave Feed water to laboratory animals
 Feed Water Quality
 Tap water*  Municipal water, TDS < 1000 ppm (2000 μS/cm)
 Operating Temperature  5~45 ℃
 Feed Water Pressure  15 - 90 psi (1 - 6 bar)
 Water Production Rate
 Ultrapure water (Type I)  Up to 2.0 L/min at 25℃
 RO water  10 to 50 L/h at 25℃
 Product Water Quality
 RO water conductivity**  Typically < 20 μS/cm
 Resistivity  18.2 MΩ·cm at 25℃
 TOC  < 10 ppb (< 5 ppb with a dual wavelength UV lamp)
 Particle (> 0.2 μm)  No particles  (with a 0.2 μm final filter or RephiBio filter)
 Microorganisms  < 0.01 cfu/ml (with a 0.2 μm final filter or RephiBio filter)
 Pyrogens (endotoxins)  < 0.001 Eu/ml (with a RephiBio filter)
 RNase  < 0.5 pg/ml (with a RephiBio filter)
 DNase  < 10 pg/mL (with a RephiBio filter)
 Dimensions
 Length x Depth x Height  30 cm × 51 cm ×48 cm
 Net Weight (Operating Weight)  22 - 25 kg (25 - 32 kg)
 Power  < 150 W
* If water hardness is less than 180 ppm, RephiLe suggests using RephiTEKT RW50211KT.
If water hardness is greater than 180 ppm, RephiLe suggests using an additional water softening device to protect the RO membrane in your system.
** Product water quality may vary depending on local feed water conditions.
Water System
 Description  Catalog No.
 Direct-Pure Water System, UP 10  RD0P0100E
 Direct-Pure Water System, UP 20  RD0P0200E
 Direct-Pure Water System, UP 30  RD0P0300E
 Direct-Pure Water System, UP 50  RD0P0500E
 Direct-Pure Water System, UP 10 and 2-Pass RO  RD0P2100E
 Direct-Pure Water System, UP 10 UV  RD0P010UE
 Direct-Pure Water System, UP 20 UV  RD0P020UE
 Direct-Pure Water System, UP 30 UV  RD0P030UE
 Direct-Pure Water System, UP 50 UV  RD0P050UE
 Direct-Pure Water System, UP 10 UV and 2-Pass RO  RD0P210UE
 Direct-Pure Water System, UP 10 set  RD0P0100EK
 Direct-Pure Water System, UP 20 set  RD0P0200EK
 Direct-Pure Water System, UP 30 set  RD0P0300EK
 Direct-Pure Water System, UP 50 set  RD0P0500EK
 Direct-Pure Water System, UP 10 and 2-Pass RO set  RD0P2100EK
 Direct-Pure Water System, UP 10 UV set  RD0P010UEK
 Direct-Pure Water System, UP 20 UV set  RD0P020UEK
 Direct-Pure Water System, UP 30 UV set  RD0P030UEK
 Direct-Pure Water System, UP 50 UV set  RD0P050UEK
 Direct-Pure Water System, UP 10 UV and 2-Pass RO set  RD0P210UEK
Cartridge Set is required for the water systems to function. Please contact RephiLe for detailed information. Cartridges and Final Filters
 Description  Catalog No.
 RephiDuo H Pack  RR300Q201
 RephiDuo U Pack  RR600Q201
 RephiDuo U Pack with a 0.2 µm final filter  RR600Q2KT
 RephiDuo U Pack, low TOC  RR600Q301
 RephiDuo U Pack, low TOC with a 0.2 µm final filter  RR600Q3KT
 0.2 µm PES high flux capsule filter  RAFFC0250
 RephiBio filter, 1/4 NTPM  RAFFB0201
Tanks and Accessories
 Description  Catalog No.
 30 L PE Tank with tank level sensor  RATANK030
 60 L PE Tank with tank level sensor  RATANK060
 100 L PE tank with level sensor  RATANK01H
 Tank vent filter with CO2 scavenger  RATANKVN1
 Tank vent filter, 5 inch  RATANKVL1
 Tank UV sanitation module with controller  RAPRC0106
 254 nm tank UV lamp  RAUV357A1
 30 L tank level sensor for D-Pure, 351 mm  RATLS9011
 60 L tank level sensor for D-Pure, 626 mm  RATLS9021
System Accessories
 Description  Catalog No.
 Wall mount kit for Direct-Pure systems  RASP532
 Dual wavelength 185/254 nm UV lamp  RAUV357B1
 RO Membrane with housing, 10 L/H  RAR0100HG
 RO Membrane with housing, 15 L/H  RAR0015HG
 RO Membrane for Direct-Pure 2-Pass RO system  RAR0200HG
 RO Membrane for Direct-Pure 50 system  RAR0B50HG
 DC recirculation pump kit, 24VDC  RASP740KT
 DC RO pump, 24V DC  RASP836KT
 DC RO Pump, 24V DC for UP 50  RASP940KT
 Feed water pump  RASP602KT
 Leak protector  RAPRC0111
Prefilters
 Description  Catalog No.
 200 lph Water softener kit  LAB0200AT
 200 lph Activated carbon filter  LAB0200AC
 RephiTEKT prefilter support (no cartridge)  RW50211KT
 RephiDuo prefilter cartridges, 4/order  LAB02CP04
 Pellet salt  LABSA1010
 Polypropylene depth filter, 10 in, 1 µm, 12/Pk  LABPA0112
 Polypropylene depth filter, 10 in, 10 µm, 12/Pk  LABPA1012
 Anti-Scale treatment filter, 4/order  LABST1004
 Activated carbon cartridge, 10 in, 12/pack  LABAC1A12
 Anti-Scale conditioning cartridge (treat hard water), 10 in, 12/pack  LABAT1012
 Prefiltration kit (two-stage)  RW10211KT
 Prefiltration kit (three-stage)  RW10311KT